Retrotec door fan 3 software

Click on windows start menu all programs retrotec fantestic integrity, or click the fantestic integrity icon on your desktop. Complete with a gauge, fan, 6 ranges, connectors, software and a 10year warranty on the fan shell. Retrotec us5102 blower door systems thermalcameraexperts. Software to record and calculate readings from fans and manometers set up to measure air leakage in enclosures usually rooms or buildings including ducts. Measure, record and report up to 6 additional building zone pressures during the automated blower door test can use multiple dg700 gauges. Retrotec test fans, blower door systems, duct testing systems and gauges have been calibrated in our laboratory which is accredited by the ansiasq national. Using a fan splitter under default conditions will override individual control. If you have an account, and are logged in, select the courses youd like to enroll in from the list below. The retrotec us340 is the complete package for residential duct leakage testing. Blower door catalog digital manometer house doctor. Learn how to input data into fantestic software from a manual blower door test. See if rooms with closed doors get pressurized by air handler running.

This is the most economical way to blow large quantities of air to test commercial, multifamily or high rise buildings. With the fan installed in the door panel, the 6120 series blower door perform fully automatic testing using the gauge, a laptop and the provided fantestic software. The 8 bladed fan comes with a maximum flow capacity of 14,102 m3h 3,917. Stacked blower door with 3 fans model description price e33fanstackdm4110v infiltec digital blower door with 3 stacked fans 110vac60hz maximum flow. Jan 03, 2012 learn how to input data into fantestic software from a manual blower door test. Rapid setup door panel with case dm2a measures and controls pressure and airflow automatically.

Retrotec door fan test report south west air energy. Retrotec us3112 blower door with model 3000 fan tequipment. This system implements a large fan, capable of up to 14,440m 3 h free air, making it applicable in tests of midsized commercial structures control this system directly via the dm32 dual channel digital pressure gauges, or via the fantestic software on your laptop to run the test automatically. Tec i dont do blower door work every day, but i do enough of it to appreciate the attention to detail that the energy conservatory tec built into its new blower door kit.

The following procedure must be repeated for every usb port on your computer. The door fan itself merely measures the size of holes in the enclosure and the pressures that may exist across them. Retrotec us3112 blower door with model 3000 fan the 10 series blower door system has three model calibrated fans in one large cloth panel door frame system. Retrotec 3101 consists of a dm32, a 3200 fan and a cloth door panel. We even have a 10 year warranty on our fan shell because you cant break it. Software to record readings from a fan and manometer set up to measure air leakage in an enclosure, and calculate results for agent retention time and peak. Save on retrotec equipment buy through green training usa. This system implements a large fan, capable of up to 14,440m 3 h free air, making it applicable in tests of midsized commercial structures. Avaliable in a number of different versions the software can record and calculate readings from the fans and manometers set up to measure air leakage. Computer software does the rest of the simulation and comes up with the prediction. Retrotec us5110 blower door with model 5000 fan large cloth panel. The energy conservatory blower door duct blaster 4. Software developer retrotec, inc january 1995 december 1999 5 years.

Blower door software setup instructions earlham cs department. Retrotec gr125 grill mask 8 case of 4 retrotec gr127 grill mask 12 case of 4 retrotec gr129 grill mask 18 case of 4 tec minneapolis duct mask 8 wideclear. Infiltec, retrotec, 2000, 3000, 5000 and 6000 series and the energy conservatory model 3, model 4 and ductblasters. Combine its singlebutton, color touchscreen, with an image oriented interface, with the powerful model 300 fan and youll see why retrotec equipment is a market leader in home performance testing. There are three primary components to a blower door. A dm32 digital pressure gauge and the umbilical cable needed to connect it to your fan. Retrotec fantestic pro available to buy from bsria instrument. Manual for fantestic integrity venting calculator manuals. The retrotec 1211 double classic blower door system with large cloth panel performs fully automatic testing using the gauge, a laptop and the provided fan testic software. Motor capable of moving up to 6,400 cubic feet of air per minute cfm. Use this guide to compare features of the two top us. Blower door operation manual for series 200, 300, and 3000 systems rev20150122.

Read on about at least 15 exclusive features you will find only with retrotec who is the worlds largest and most advanced blower door manufacturer. It can be configured for completely automated test fan operation, data collection and report generation. A retrotec door fan with a model beginning with q such as a q46. Retrotec us3112 blower door system retrotec us3111 blower.

Rapid setup door panel with case dm32 measures and controls pressure and airflow automatically. Retrotec model q46 door fan minneapolis model 3 blower door. Retrotec us3212 blower door with model 3000 double fan this is a high output air leakage test system, featuring two of the model 3000 calibrated fans, a tight fitting doublehole. Qhwhurwrrov frp qhwhurwrrov frp retrotec us3112 blower door system retrotec us3111 blower door system retrotec us3102 blower door system. Fantestic integrity software enclosure integrity testing retrotec. The fan handle can be oriented to the right or left to compliment the position of the console. Retrotec 6101 hipower air leakage test system has a maximum. Blower door testing software for automated fan operation, data collection, and. The tool requires the blower door fan, the target air permeability and the size of the building surface area to be identified. Commercial blower door testing energy conservation. Please only enroll in one each of level 1 andor level 2. Retrotec instruments from bsria instrument solutions. The fan capacity calculator works on the basis of some assumptions such as a quality power supply and running into a free air unobstructed route. Fantestic lite blower door testing software retrotec.

Retrotec fantestic pro available to buy from bsria. The testing technician should be certified to at least level 2 for conducting a single doorfan test and at least level 3 when conducting a dual doorfan test. I have used both tec and retrotec blower door kits and found them trustworthy and rugged. Retrotec 3 fan system available to hire from bsria. Retrotec offers three levels of air tightness training. The e43 door fan system included an analog gauge clip which contains two 60 pa gauges and a 500 pa gauge as shown on the second image in figure 3. Retrotec door fan test report tester information rachel simpkins south west air energy 5 kel avon close truro, cornwall united kingdom, tr1 1an telefon. Developed handheld digital micromonometer used to measure room pressure differences measured in units of pascals. Airchange rate, ela or airflow per unit area results without a computer. Alternatively, simply key the desired test pressure into the gauge and read air changes or leakage per unit area in real time directly from the touchscreen gauge. Retrotec us6100 blower door with model 6000 fan cloth panel all the features of a model 5100 but double the power. Q5e with a sleek and professional appearance, the 3120 series blower doors boast a powerful, 1.

Small and versatile xml data storage with reports in microsoft word automatic updating over the internet fully compliant with astm and european norms manual or fully automatic. How to run an automatic blower door test using fantestic software. The new tec blower door kit featuring the dg computerpressure gauage. Retrotec us5100 blower door with model 5000 fan cloth panel. Retrotec us3212 blower door with model 3000 double fan. Tap set speed to run the fan at a particular speed the gauge can automatically control the fan speed on retrotec systems to achieve a specific fan speed, entered by the user. To connect the gauge to a retrotec fan or variable speed fan drive 41. Retrotec us3212 blower door system retrotec us3211 blower door system fantestic retrotecs latest building air leakage test software many new features including. Fantestic software will automatically control the fan speed and take from 2 to 20,000 readings with no operator involvement provided you have. Begin by holding the fan sideways and tipping it so that the foot protrusion extends through the panel. The software walks the user through all the steps in a controlled way to ensure each step is done in accordance with the chosen standard. Blower door software setup instructions earlham cs. I have used both tec and retrotec blower door kits and found them trustworthy and rugged i once asked tec principal gary nelson if there.

Complete package with gauge, fan, 6 ranges, cloth door panel, connectors, software, and a 10year warranty on the fan shell. Reading the pressure on an analog gauge is simply a matter of determining where the needle is pointing on the gauge. Retrotec us3112 blower door system retrotec us3111. Retrotec us3211 energy conservation linkedin slideshare. Retrotec us3212 blower door with model 3000 double fan this is a high output air leakage test system, featuring two of the model 3000 calibrated fans, a tight fitting doublehole cloth door panel, and a dm32 gauge. The retrotec q5e system comes with a rigid frame adaptable to a wide range of door sizes. Setting up for a test with alaskas akwarm software. Retrotec fantestic software is used for residential and large building blower door testing.

High powered blower door system all the features of a model 5100 but double the power. Retrotec blower door test equipment duct testing equipment. Retrotec your central resource for product support that includes manuals, datasheets, technical specifications, videos and software. The energy conservatory blower door duct blaster products.

A computer with a high speed usb port to connect to the retrotec model dm32 digital gauge. Fantestic integrity access from the settings menu as described in the next sections. Retrotec blower door system with x3 3000 series fans with rings a b. All retrotec door fan systems can be connected to an analog gauge.

Residential and large building blower door testing software for completely automated test fan operation, data collection and report generation. Fantestic software from retrotec can calculate the annual cost for both heating. A retrotec door fan with a model beginning with q q46 for example fantestic software will automatically control the fan speed and take from 2 to 20,000 readings with no operator involvement. Retrotec model q4e consists of a dm2a, a 3200 fan and a cloth door panel. This system will test a wide range of enclosures, from super leaky to super tight. Semiauto test option allows computerized data collection while manually controlling the blower door fan. This is a high output air leakage test system ideal for testing large. Quick connect frame with extra crossbar for stability and gauge mounting. Retrotec us5100 series blower door with dm32 touchscreen. A retrotec gauge and door fan or other manufacturer fan with retrotec fan speed. Retrotec fantestic pro software trutech tools, ltd. With a sleek and professional appearance, the 6120 series blower doors boast a powerful, 1. Retrotec 3 fan system available to hire from bsria instrument. Testers who have completed any part of retrotecs training program are listed on our website at.

640 926 32 377 577 798 904 1236 1345 45 1472 1448 21 1338 43 795 969 1513 1554 442 525 375 927 92 33 904 271 692 593 422 107 1193 212